Siemens Skyra Open-Bore 3T Scanner Information

Scanner

Siemens 3T Skyra

  • 70 cm bore
  • 173 cm length
  • VQ Gradients - 45 mT/m and slew rate of 200 mT/m/ms
  • Tim 102x32 RF System
  • 550 lbs Patient Table Weight Capacity - with vertical lift
  • Avotec Silent Vision SV-6011 LCD projection system
  • Avotec Silent Scan SS-3100 audio system
  • Current Designs button response units
  • 64-channel MRI-compatible EEG (Brain Vision)

3T RF Coils

  • 20 Channel Head Matrix Coil
  • 4 Channel Neck Matrix Coil
  • 16 Channel Neurovascular Matrix Coil
  • 24 Channel Spine Matrix Coil
  • 12 Channel Body Matrix Coil (quantity 2)
  • 4 Channel Shoulder Coil
  • 15 Channel Tx/Rx Knee Coil
  • 8 Channel Wrist Coil
  • 8 Channel Foot/Ankle Coil
  • 4 Channel Flex Coil Large
  • 4 Channel Flex Coil Small

3T Application Packages

  • Neuro Suite
  • Angio Suite
  • Cardiac Suite
  • Onco Suite
  • Breast Suite
  • Ortho Suite
  • Pediatric Suite
  • Scientific Suite
  • iPAT and iPAT Extensions - Parallel Imaging in 2 directions simultaneously
  • 2D/3D PACE - navigator based motion correction for cardiac and body imaging
  • SPACE - 3D Turbo Spin Echo - whole-body 3D imaging reduces SAR. T2, T1, PD and dark fluids
  • Advanced Cardiac Imaging Package
  • Flow Quantification Package
  • Argus Flow post-processing software
  • Argus 4D Ventricular Function post-processing software
  • In-Line Ventricular Function post-processing software
  • BLADE - whole-body real-time motion correction - any plane, any contrast
  • Composing - stitching software
  • In-Line Composing - stitching simultaneous to image acquisition
  • In-Line Diffusion - automated processing of ADC-maps, TRACE images
  • Diffusion Tensor Imaging
  • Diffusion Tensor Imaging Evaluation
  • DTI Tractrography
  • In-Line Perfusion - automated processing of GBP, PBP, TTP
  • Tissue 4D - visualize and post-processing of dynamic contrast enhanced data sets for pharmacokinetic modeling
  • Neuro Perfusion Evaluation - post-processing of brain perfusion data sets - relCBV, relCBF, relMTT, PBP, TTP
  • Arterial Spin Labeling - non-contrast neuro perfusion
  • SWI - susceptibility Weighted Imaging
  • In-Line BOLD - real-time calculation & display of statistical (t-value) images during measurement of fMRI paradigms
  • 3D PACE - motion correction for BOLD studies
  • BOLD 3D Evaluation - comprehensive processing and visualization for BOLD fMRI studies
  • fMRI Trigger - optical trigger signal to trigger external stimulation devices for fMRI experiments
  • Single Voxel Spectroscopy - proton spectra from single voxel
  • Spectroscopy Evaluation - post-processing of spectroscopy data sets
  • 2D Chemical Shift - proton 2D chemical shift (multi-voxel)
  • 3D Chemical Shift - proton 3D chemical shift (multi-voxel)
  • Mapit - cartilage mapping
  • Image Fusion - color overlays for cartilage mapping
  • CISS/DESS - high resolution 3D neuro (CISS) and ortho (DESS) sequences
  • Expert-i - remote access via network) to the scanner console for planning and processing support