Siemens Skyra Open-Bore 3T Scanner Information
Siemens 3T Skyra
- 70 cm bore
- 173 cm length
- VQ Gradients - 45 mT/m and slew rate of 200 mT/m/ms
- Tim 102x32 RF System
- 550 lbs Patient Table Weight Capacity - with vertical lift
- Avotec Silent Vision SV-6011 LCD projection system
- Avotec Silent Scan SS-3100 audio system
- Current Designs button response units
- 64-channel MRI-compatible EEG (Brain Vision)
3T RF Coils
- 20 Channel Head Matrix Coil
- 4 Channel Neck Matrix Coil
- 16 Channel Neurovascular Matrix Coil
- 24 Channel Spine Matrix Coil
- 12 Channel Body Matrix Coil (quantity 2)
- 4 Channel Shoulder Coil
- 15 Channel Tx/Rx Knee Coil
- 8 Channel Wrist Coil
- 8 Channel Foot/Ankle Coil
- 4 Channel Flex Coil Large
- 4 Channel Flex Coil Small
3T Application Packages
- Neuro Suite
- Angio Suite
- Cardiac Suite
- Onco Suite
- Breast Suite
- Ortho Suite
- Pediatric Suite
- Scientific Suite
- iPAT and iPAT Extensions - Parallel Imaging in 2 directions simultaneously
- 2D/3D PACE - navigator based motion correction for cardiac and body imaging
- SPACE - 3D Turbo Spin Echo - whole-body 3D imaging reduces SAR. T2, T1, PD and dark fluids
- Advanced Cardiac Imaging Package
- Flow Quantification Package
- Argus Flow post-processing software
- Argus 4D Ventricular Function post-processing software
- In-Line Ventricular Function post-processing software
- BLADE - whole-body real-time motion correction - any plane, any contrast
- Composing - stitching software
- In-Line Composing - stitching simultaneous to image acquisition
- In-Line Diffusion - automated processing of ADC-maps, TRACE images
- Diffusion Tensor Imaging
- Diffusion Tensor Imaging Evaluation
- DTI Tractrography
- In-Line Perfusion - automated processing of GBP, PBP, TTP
- Tissue 4D - visualize and post-processing of dynamic contrast enhanced data sets for pharmacokinetic modeling
- Neuro Perfusion Evaluation - post-processing of brain perfusion data sets - relCBV, relCBF, relMTT, PBP, TTP
- Arterial Spin Labeling - non-contrast neuro perfusion
- SWI - susceptibility Weighted Imaging
- In-Line BOLD - real-time calculation & display of statistical (t-value) images during measurement of fMRI paradigms
- 3D PACE - motion correction for BOLD studies
- BOLD 3D Evaluation - comprehensive processing and visualization for BOLD fMRI studies
- fMRI Trigger - optical trigger signal to trigger external stimulation devices for fMRI experiments
- Single Voxel Spectroscopy - proton spectra from single voxel
- Spectroscopy Evaluation - post-processing of spectroscopy data sets
- 2D Chemical Shift - proton 2D chemical shift (multi-voxel)
- 3D Chemical Shift - proton 3D chemical shift (multi-voxel)
- Mapit - cartilage mapping
- Image Fusion - color overlays for cartilage mapping
- CISS/DESS - high resolution 3D neuro (CISS) and ortho (DESS) sequences
- Expert-i - remote access via network) to the scanner console for planning and processing support